Archival: Panel-Mount Peakmeters 40 x 190 mm
These RTW peak program meters in standard broadcasting cassettes (40 x 190 mm) feature high precision, robust design and long-lived electronics that don’t need adjustment for demanding applications in studios, broadcasting, network control rooms, outside broadcasting units, analog and digital mastering. All units use reliable gas plasma displays (neon orange), guaranteeing excellent legibility even under poor lighting and outstanding precision thanks to the very high resolution (201 segments per channel).
The panel-mount peak program meters are available in five basic versions with different instrumentation and with customary standards (Digital, DIN, British, Nordic, ARD+9).
Features
- Panel-mount units in metal cassettes with standard dimensions: 40 x 190 mm, 107 mm depth
- High-resolution, 201-segment gas plasma display, scale length 127 mm
- Sandwich scale for horizontal or vertical installation
- All models conform to the applicable standards (IRT 3/6, British, Nordic)
Additional features of the analog instruments:
- Power supply 24 V, +/-15 V DC
- Standard 32-pin DIN 41612/C connector
- Transformer-balanced inputs (except 1113G: electronically balanced)
- Input sensitivity +6 dBu (British +8 dBu)
- Measurement range -50 dB to +5 dB (DIN versions)
Additional features of the digital instruments:
- Power supply 22–30 V DC
- Standard 64-pin DIN 41612/C connector
- Transformer-balanced AES/EBU input, input signals actively buffered
- Digital scale -60 dB FS to 0 dB FS, also quasi-DIN or [ARD+9]
- User-adjustable headroom markers
- Sampling rates 27 kHz to 96 kHz
- Overload display with adjustable sensitivity and attack time
- Peak hold display
Archived Models
DIN Standard
Analog inputs (transformer balanced, except 1113G), DIN scale (-50 to +5 dB, reference level +6 dBu at 0 dB mark, overload range 0 to 5 dB), integration time 10 ms, 201 segments gas plasma displays
1113G - no longer available -
2-ch. peakmeter with electronically balanced inputs
1115G - no longer available -
2-ch. peakmeter, peak memory, 20 dB gain
1117G - no longer available -
2-ch. peakmeter, peak memory, 20 dB gain, Fast mode (1 ms), peak hold
1119G - no longer available -
2-ch. peakmeter, peak memory, 20 dB gain, Fast mode (1 ms), phase meter
1019GL - no longer available -
2-ch. peakmeter, peak memory, 20 dB gain, Fast mode (1 ms), phase meter, peak hold, loudness
BRITISH Standard
Analog inputs (transformer balanced), British IIa scale ("1" to "7", reference level +8 dBu at "6" mark, overload range "6" to "7"), integration time 10 ms, 201 segments gas plasma displays
1130G - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain
1134G - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain, Fast mode (1 ms), phase meter
1034GL - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain, Fast mode (1 ms), phase meter, peak hold, loudness
NORDIC Standard
Analog inputs (transformer balanced), Nordic N9 scale (-42 to +12 dB, reference level +6 dBu at +6 dB mark, overload range +6 to +12 dB), integration time 5 ms, 201 segments gas plasma displays
1139G - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain, Fast mode (1 ms), phase meter
1039GL - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain, Fast mode (1 ms), phase meter, peak hold, loudness
DIGITAL Standard
Digital AES/EBU inputs (transformer balanced), digital outputs, sampling rates 27 to 96 kHz, Digital scale (-60 to 0 dB FS, selectable headroom, preset to -9 dB FS), overload indicators, integration time sample, 201 segments gas plasma displays
11520G - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain
11520G-DIN - no longer available -
same as 11520G, but with quasi-DIN scale (-50 to +5 dB, -9 dB FS digital level adjusted to 0 dB mark), integration time 10 ms, 20 dB gain
11519G - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain, phase meter
11519G-DIN - no longer available -
same as 11519G, but with quasi-DIN scale (-50 to +5 dB, -9 dB FS digital level adjusted to 0 dB mark), integration time 10 ms, 20 dB gain
11529G - no longer available -
2-ch. peakmeter, peak memory, 40 dB gain, phase meter, peak hold, loudness
11529G-DIN - no longer available -
same as 11529G, but with quasi-DIN scale (-50 to +5 dB, -9 dB FS digital level adjusted to 0 dB mark), integration time 10 ms, 20 dB gain
DIGITAL Special Version for broadcast applications [ARD+9]
11528G - no longer available -
Digital AES/EBU inputs (transformer balanced), digital outputs, sampling rates 27 to 96 kHz, measuring range -60 to 0 dB FS, scale range -60 to +9 dB, fixed headroom (-9 dB FS at 0 dB mark), double indication: peak level (0 ms) with either peak level (10 ms) or RTW loudness, overload indicators, integration time sample, 201 segments gas plasma displays, peak memory, 40 dB gain, phase meter, loudness
Analog Phase Meter
1170C - no longer available -
2 analog inputs, 2 analog outputs, input level -20 to +22 dBu, 21 segment LED display, scale -1 r to + 1 r
Accessories
1018 - no longer available -
Table-top housing without power supply and without connectors for all 40 x 190 mm panel-mount instruments
1020E - no longer available -
Table-top housing with power supply and connectors, for analog 40 x 190 mm instruments: XLR input connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
10220 - no longer available -
Table-top housing with power supply and connectors, for digital 40 x 190 mm instruments: XLR input and output connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
1128H - no longer available -
Power pack and bracket for mounting to 19“/1U rack-mount kits, enables the mounting of analog 40 x 190 mm instruments into 19“ environments: XLR input connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
11280 - no longer available -
Power pack and bracket for mounting to 19“/1U rack-mount kits, enables the mounting of digital 40 x 190 mm instruments into 19“ environments: XLR input and output connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
12961 - no longer available -
19“/1U rack-mount kit, black, for one 40 x 190 mm instrument and one 1200 series instrument
12993 - no longer available -
19“/1U rack-mount kit, black, for one 40 x 190 mm instrument
12994 - no longer available -
19“/1U rack-mount kit, black, for two 40 x 190 mm instruments
12996 - no longer available -
Cover plate and mounting frame for 40 x 190 mm instruments, overall dimensions 210 x 60 mm
13671 - no longer available -
Blank panel for covering the cut-out for the 1200 series instrument of the 12691 rack-mount kit
13721 - no longer available -
Blank panel 40 x 190 mm with M3 screws for covering the 40 x 190 mm cut-out of the 12691 rack-mount kit or for one of the cut-outs of the 12994 rack-mount kit
13973 - no longer available -
Clamping lock fastening kit for retrofitting 40 x 190 mm standard panel mount cassette instruments
Download Information